CCCKR - 6TLFP;BATTERY ELECTRIC STORAGE,DRY
- MSDS: CCCKR
- Manufacturer: EAST PENN MFG CO INC
- Product Name: 6TLFP;BATTERY ELECTRIC STORAGE,DRY
- National Stock Number: 6140-01-431-1172
Product Identification
Product ID:6TLFP;BATTERY ELECTRIC STORAGE,DRY
MSDS Date:04/01/1994
FSC:6140
NIIN:01-431-1172
Kit Part:Y
MSDS Number: CCCKR
Responsible Party
LYON STATION, PA 19536
US
Emergency Phone: 800-424-9300(CHEMTREC)
Info Phone: 610-682-6361
Cage: 04055
Contractor
Telephone: 610-682-6361
Cage: 04055
Ingredients
LEAD (SARA 313) (CERCLA)
CAS: 7439-92-1
RTECS: OF7525000
Fraction By Weight: 97%
OSHA PEL SEE 1910.1025
ACGIH TLV: 0.05MG/M3, A3; 9596
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
Hazards
LD50 LC50 Mixture:TLV FOR LEAD IS 0.15MG/M*3
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:NO HAZARD EXISTS IN NORMAL USE.THIS
BATTERY CONTAINS LEAD.LEAD ACCUMULATES IN BONES AND BODY TISSUES
AND CAUSES LEAD POISONING.MAY CAUSE SKIN AND EYE
IRRITATION.CHRONIC:MAY DAMAGE CENTRAL NERVIOUS SYS TEM,KIDNEYS AND
REPRODUCTIVE SYSTEM.
Explanation of Carcinogenicity:LEAD IS IARC-2B.
Effects of Overexposure:ACUTE:HEADACHE,NAUSEA,VOMITING,ABDOMINAL
SPASMS,FATIGUE,WEIGHT LOSS,ANEMIA,PAIN IN ARMS,LEGS AND
JOINTS.CHRONIC:ELEVATED LEAD LEVELS IN BLOOD.
Medical Cond Aggravated by Exposure:PREGNANT WOMEN AND CHILDREN SHOULD
AVOID EXPOSURE TO LEAD.
First Aid
First Aid:NO FIRST AID REQUIRED IN NORMAL USE.IF LEAD EXPOSURE
OCCURS,SEEK MEDICAL ATTENTION.
Fire Fighting
Flash Point:NONE
Extinguishing Media:DRY CHEMICAL,CARBON DIOXIDE,WATER SPRAY OR FOAM.
Fire Fighting Procedures:USE FULL FIRE FIGHTING GEAR AND A
SELF-CONTAINED BREATHING APPARATUS OPERATED IN THE POSITIVE
PRESSURE MODE(HMIS).
Unusual Fire/Explosion Hazard:DECOMPOSITION PRODUCTS MAY BE
TOXIC(HMIS).
Accidental Release
Spill Release Procedures:USE PROPER RESPIRATORY AND PROTECTIVE
EQUIPMENT.AVOID EXPOSURE TO THE COMPONENTS OF THIS BATTERY.PLACE
WASTE IN A PROPER CONTAINER FOR DISPOSAL.
Neutralizing Agent:NOT APPLICABLE.
Handling
Handling and Storage Precautions:STORE IN A COOL,DRY PLACE.AVOID HIGH
HEAT.AVOID SHORTING AND DAMAGE TO CASE(HMIS).
Other Precautions:FOLLOW LABEL DIRECTIONS.
Exposure Controls
Respiratory Protection:USE A NIOSH/MSHA APPROVED RESPIRATOR FOR LEAD
FUMES IF LEAD EXPOSURE IS SUSPECTED.
Ventilation:NOT NEEDED IN NORMAL SERVICE.
Protective Gloves:WORK GLOVES,AS NEEDED.
Eye Protection:SAFETY GLASSES(HMIS).
Other Protective Equipment:PROTECTIVE CLOTHING,AS NEEDED.PROVIDE A
LOCAL EYE WASH STATION AND SAFETY SHOWER.
Work Hygienic Practices:ALWAYS PRACTICE GOOD PERSONAL HYGIENE AND SAFE
WORK PRACTICES.
Supplemental Safety and Health
KEY1;N1.
Chemical Properties
HCC:N1
Solubility in Water:INSOLUBLE
Appearance and Odor:NOT REPORTED.
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MFR.
Stability Condition to Avoid:HIGH HEAT(HMIS).
Hazardous Decomposition Products:LEAD FUMES(HMIS).
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL,STATE AND
LOCAL LAWS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.